The Legor gf 2N Flash Gold Plating Solution contains 0.8g/l of gold and requires a Platinised Titanium or Stainless Steel Anode in a 1:1 ratio. This solution is supplied in a ready to use form for bath plating.

​

Operating Data -


pH - range - 10.00-10.50 - optimal - 10.3
Voltage - range - 3.3-5.5 - optimal - 4.5
Current density (A/dm²) - range - 0.5-2.0 - optimal - 1.2
Working Temperature - range - 55-65°c - optimal - 60°c
Exposure time (sec) - range - 20-50 - optimal - 40

 

Legor 2N flash gold bath plating solution deposits a uniform shiny layer in 2N colour, this colour can be described as a pale yellow colour with green undertones and is considered to match 18ct yellow gold in most international markets. This bath plating solution is designed as a decorative flash plate that deposits up to the thickness of 0.2mircon.